Marantz DV4100 Manuel d'utilisateur Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 143
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
60
14.4 LOOP TEST
At the start of the loop test, the display will show the result of
the interactive player test:
Figure 14-25
The left side of the display contains a 3-digit code, which can
have a value between 000 and 111. These values are to be
interpreted as follows:
Figure 14-26
The loop test will perform the same nuclei as the dealer test,
but it will loop through the list of nuclei indefinitely. The display
of the DVD player will display not only the three digits indicating
correct/faulty modules and the last found error code (as
mentioned, faults are detected as far as they can be within the
scope of the diagnostic software), but also a loop counter
indicating how many times the loop has been gone through.
Example:
Figure 14-27
The number after the hyphen indicates the number of times the
loop test has been performed; the 4 digits at the right side of the
display show the last error that was found when running the
loop test: the leftmost two digits of this code indicate which
nucleus resulted in a fault; the rightmost two digits refer to the
faultcode within that nucleus. For further explanation of this
error code, see list of error codes below.
Figure 14-28
Displayed
Value
Indication for each module
Basic Engine Mono
PCB
Display
PCB
000 ok ok ok
001 ok ok faulty
010 ok faulty ok
011 ok faulty faulty
100 faulty ok ok
101 faulty ok faulty
110 faulty faulty ok
111 faulty faulty faulty
FAULTY
MODULE(S)
LOOP
COUNTER NUCLEUS ERROR
ERROR CODES LOOP TEST
ERROR CODE NUCLEUS NUMBER ERROR DESCRIPTION
0601
6 Calculated checksum of FLASH is not correct
0901
9 The DVD DRAM is faulty
1104
11 I2C bus busy before start
1102
NVRAM access time-out
1103
No NVRAM Acknowledge
1104
NVRAM reply time-out
1201
12 I2C bus busy
1202
I2C bus not working
1203
Slave controller not responding
1204
Slave response is not correct
1301
13 Parity error from basic engine to serial
1302
Parity error from serial to basic engine
1303
No communication between serial and basic engine
1304
Communication time-out error
1601
16 The SDRAM is faulty