Marantz DV4500 Manuel de service Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
1-7-4
E59M2BLP
Power Supply Block Diagram
IC1006
(SHUNT REGULATOR)
REG
AC1001
AC CORD
F1001
LINE
FILTER
L1001
D1001, D1002
D1004, D1005
Q1003
Q1001
2
4
7
3
4
IC1001
ERROR
VOLTAGE DET
T1001
11
12
13
15
14
16
17
18
SWITCHING
SWITCHING
CONTROL
1
2
6
BRIDGE
RECTIFIER
HOT
HOT CIRCUIT. BE CAREFUL.
D1003
RECTIFIER
D1030
RECTIFIER
D1016
RECTIFIER
Q1016
TO SYSTEM
CONTROL/SERVO
BLOCK DIAGRAM
INV-POWCON
Q1005
Q1011
Q1015
Q1002
Q1014
CN1001
Q1004
-FL
EV+5V
F1
P-ON+11V
EV+3.3V
P-ON+5V
1,2
EV+1.2V
3,4,5
EV+3.3V
8,9
EV+11V
7
P-ON+5V
6
P-ON+3.3V
17
PWRCON
+1.2V
REG.
IC1002
D1006
SCHOTTKY
BARRIER
SCHOTTKY
BARRIER
D1008
F2
AV CBA
TO CN401
Q1008
LATCH
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
T1.6A L 250V
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 47 48

Commentaires sur ces manuels